ON BOARD DIAGNOSTIC (OBD) SYSTEM
DC/DC converter that is corresponded to on board diagnostic system detects malfunction automatically, when system error occurs.
Malfunction information is stored DC/DC converter memory as a DTC that can be obtained with CONSULT.
COUNTER SYSTEM
Counter system counts up at every operation of power switch from OFF to ON under condition that the same malfunction is not detected. On the other hand, if the same DTC as memorized one is detected again, the count is reset and the counter system counts up again from "0".
DTC AND FREEZE FRAME DATA
DC/DC converter can save multiple DTCs but can only save one freeze frame data.
After DC/DC converter detects a malfunction and saves DTC and freeze, frame data, if a different malfunction is detected, multiple DTCs are confirmed, but only first freeze frame data.
DTC and freeze frame data can be deleted when self-diagnostic is deleted.
FUNCTION
Diagnosis test mode | Function |
---|---|
C/U identification information | Displays parts No. of DC/DC converter |
Self-diagnosis result | Can immediately read and delete DTC and freeze frame data.* |
Data monitor | Can read input and out put data of DC/DC converter |
*:When memory of DC/DC converter is deleted, the following diagnosis information are also deleted
DTC
Freeze frame data
Corresponded operation history and operation count.
SELF-DIAG RESULTS MODE
Self Diagnostic Item
Regarding items of DTC, Refer to DTC Index.
IGN Counter
IGN counter is displayed in Freeze Frame Data (FFD). It displays the number of operations of power switch from OFF to ON after DTC recovery to normal. Refer to Diagnosis Description.
CAN malfunction (U1000)
The number "0" is displayed when a malfunction is detected now.
The displayed number counts up at each operation of power switch from OFF to ON after recovery to normal, such as 1 → 2 → 3...38 → 39.
The number is fixed to 39 until the self-diagnosis results are erased if it is over 39.
Except CAN malfunction (Except U1000)
The number "0" is displayed when a malfunction is detected now.
The displayed number counts up at each operation of power switch from OFF to ON after recovery to normal, such as 1 → 2 → 3...254 → 255.
The number is fixed to 255 until the self-diagnosis results are erased if it is over 255.
Freeze Frame Data
The Freeze Frame Data shows the status of the vehicle when the DTC is detected and is useful for recreating the status when the malfunction occurred.
Freeze frame data item | Function |
---|---|
Input voltage | Displays AC current value of DC/DC converter |
DC/DC converter internal rectifier voltage 1 | Displays DC / DC converter internal rectified voltage 1. |
DC/DC converter internal rectifier voltage 2 | Displays DC / DC converter internal rectified voltage 2. |
DC/DC converter high voltage primary transformer current 1 | Displays high voltage primary converted current 1 of DC/DC converter |
DC/DC converter high voltage primary transformer current 2 | Displays high voltage primary converted current 2 of DC/DC converter |
DC/DC converter low voltage transistor output current 1 | Displays low voltage side output current 1 of DC/DC converter |
Low voltage transistor 1 temperature | Displays low voltage side transistor 1 temperature |
Low voltage transistor 2 temperature | Displays low voltage side transistor 2 temperature |
DC/DC converter 14V output voltage | Displays DC/DC converter output voltage |
DC/DC converter activation signal | Displays DC/DC converter start signal received from VCM |
DC/DC converter output voltage command value | Displays output voltage command value received from VCM |
DC/DC converter high voltage input current | Displays high voltage current value input to DC/DC converter |
DC/DC converter output current | Displays DC/DC converter output current |
DC/DC converter temperature | Displays DC/DC converter temperature |
DC/DC converter available output current | Displays possible output current value calculated by DC/DC converter |
Service plug status (CAN) | This is displayed but not used. |
Power ON integrated time | Displays the elapsed time since power switch is turned on. |
12V battery voltage | Displays 12 V battery voltage |
VCM wake up command | Displays start command signal from VCM |
DC/DC converter high voltage input voltage | Displays input high voltage value to DC/DC converter |
DC/DC converter supply voltage | Displays DC/DC converter internal voltage |
DC/DC converter high voltage internal input current | Displays DC/DC converter internal high voltage current |
DC/DC converter estimation coolant temperature 1 | Displays estimated coolant temperature |
DC/DC converter estimation coolant temperature 2 | Displays estimated coolant temperature |
DC/DC converter internal current sensor supply voltage | Displays supplied voltage to current sensor in DC/DC converter |
High voltage overcurrent | This is displayed but not used. |
DC/DC converter Input voltage internal monitor voltage | Displays internal monitor voltage of input voltage to DC / DC converter. |
DC/DC converter Input voltage internal monitor quality | This is displayed but not used. |
DC/DC converter internal error 1 | Displays DC/DC converter internal malfunction 1 |
DC/DC converter internal error 2 | Displays DC/DC converter internal malfunction 2 |
DC/DC converter high voltage internal voltage range check | Displays check range of internal voltage of DC/DC converter high voltage side. |
DC/DC converter low voltage internal short circuit counter 1 | Displays number of short circuit occurrence in DC/DC converter low voltage circuit. |
DC/DC converter low voltage internal short circuit counter 2 | Displays number of short circuit occurrence in DC/DC converter low voltage circuit. |
DC/DC converter calculate output current 1 | Displays output current value calculated by DC/DC converter. |
DC/DC converter calculate output current 2 | Displays output current value calculated by DC/DC converter. |
DC/DC converter internal output voltage monitor 1 | Displays internal output voltage monitor 1 of DC/DC converter |
DC/DC converter internal output voltage monitor 2 | Displays internal output voltage monitor 2 of DC/DC converter |
DC/DC converter internal error monitor | This is displayed but not used. |
DC/DC converter internal SPI error monitor | This is displayed but not used. |
DC/DC converter internal MPU error monitor | This is displayed but not used. |
DC/DC converter internal MPU data monitor | This is displayed but not used. |
DC/DC converter internal MPU trap monitor | This is displayed but not used. |
DC/DC converter internal MPU trap adress monitor | This is displayed but not used. |
Odometer/Trip meter | Displays mileage when DTC is detected |
DTC count | Displays number of DTC is occurred. |
DATA MONITOR MODE
NOTE:
The following table includes information (items) inapplicable to this Nissan Ariya vehicle. For information (items) applicable to this vehicle, refer to CONSULT display items.
Monitor item | Unit | Function |
---|---|---|
Input voltage | V | Displays voltage of DC/DC converter input side (high power battery side) |
DC/DC converter activation signal | ー | Displays start signal of DC/DC converter received from VCM |
DC/DC converter status | ー | Displays status of DC/DC converter |
DC/DC converter output voltage command value | V | Displays output voltage command value that VCM requests DC/DC converter |
DC/DC converter output current | A | Displays DC/DC converter output current |
DC/DC converter temperature | % | Displays DC/DC converter temperature |
DC/DC converter available output current | A | Displays possible output current calculated by DC/DC converter |
12V battery voltage | V | Displays 12 V battery voltage |
DC/DC converter input power | kw | Displays DC/DC converter input power |
DC/DC converter error type | ー | Displays malfunction type of DC/DC converter |
Beginning midst our that fourth appear above of over, set our won’t beast god god dominion our winged fruit image