Diagnosis System (lbc). Consult Function

Diagnosis Description

APPLICATION ITEM

CONSULT performs the following functions by communicating with Li-ion battery controller (LBC).

X: Applicable

Item Function

HIGH VOLTAGE BATTERY

(Main CPU)

HIGH VOLTAGE BATTERY 2

(Sub CPU)
Self Diagnostic Results

Display non-network DTC which LBC memorizes.

Can read and erased* Self Diagnostic Results that LBC judged.
X X
Data Monitor Can read input and output data of LBC X X
Work Support Can adjust components and systems quickly and accurately according to CONSULT display. X  
ECU Identification Can read parts No. of LBC. X X

*: The following diagnosis information is erased when LBC memory is erased.

  • DTC

  • Freeze frame data (FFD)

SELF DIAGNOSIS RESULTS

  • DTC Item

    • For the item “DTC and 1st trip DTC", Refer to DTC Index.

  • How to read DTC and 1st trip DTC

    DTC and 1st trip DTC related to the malfunction are displayed on "Self Diagnostic Results" mode of CONSULT. "TIME" indicates the number of times the Nissan Ariya vehicle has been driven since the last DTC was detected.

    • If DTC is currently detected, the “TIME” is displayed as “0”.

    • When LBC stores 1st trip DTC, “TIME” is displayed as “1t”.

    • DTCs with “TIME” other than “0” or “1t” are defected that was occurred in the past.

  • How to Erase DTC

    NOTE:

    If power switch remains ON after repair work, check that power switch in turned OFF.

    Then, wait for 10 seconds or more, and turn ON again.

    NOTE:

    Erase DTC in order first "HIGH VOLTAGE BATTERY 2" then next "HIGH VOLTAGE BATTERY".

    1. Select “HIGH VOLTAGE BATTERY 2” with CONSULT.

    2. Select “Self Diagnostic Results” mode.

    3. Touch “ERASE”. [DTC stored in LBC (Sub CPU) is erased.]

    4. Select “HIGH VOLTAGE BATTERY” with CONSULT.

    5. Select “Self Diagnostic Results” mode.

    6. Touch “ERASE”. [DTC stored in LBC (Main CPU) is erased.]

  • Freeze frame data (FFD) and freeze frame data of 1st trip DTC

    HIGH VOLTAGE BATTERY (Main CPU)
    Monitored item Unit Remark
    Odometer/Trip meter Km ODO/TRIP meter at the moment a DTC is detected is displayed.
    Diagnostic trouble code count count Displays the number of DTC detections.
    SOC input calculated value % Displays SOC calculated value
    Battery SOC % Displays battery charge level (SOC)
    Total battery voltage V Displays total voltage of the Li-ion battery
    Maximum cell voltage V Displays the highest cell voltage in each cell.
    Maximum voltage cell No

    Displays cell No. of highest voltage cell.

    NOTE:

    Cell No. is shown 0 to 95. For comparison, Refer to Component Description.

    Minimum cell voltage V Displays the lowest cell voltage in each cell.
    Minimum voltage cell No

    Displays cell No. of lowest voltage cell.

    NOTE:

    Cell No. is shown 0 to 95. For comparison, Refer to Component Description.

    Battery current A Displays current value of Li-ion battery
    Maximum available power kW Displays maximum effective power.
    Power supply voltage V Displays 12 V power supply voltage to LBC
    Average temperature °C Displays average temperature of each module
    Lowest module temperature °C Displays lowest temperature of module.
    Highest module temperature °C Displays highest temperature of module.
    Maximum Charge Power kW Displays maximum charge power
    Water temperature sensor voltage V Displays voltage of water temperature sensor
    CPU temperature °C Displays CPU temperature of LBC
    CPU power supply voltage V Displays CPU power supply voltage of LBC
    Water temperature °C Displays battery coolant temperature
    Interlock switch 1 Off/On/Short to power/Resistance NG/Short to ground Displays lock status between high voltage harness (FR) and service plug
    Highest temperature module °C Displays module No. that shows maximum temperature.
    Lowest temperature module °C Displays module No. that shows minimum temperature.
    LBC status 0 – 9

    Displays control status of LBC

    0: No request

    1: During normal charge

    4: During state transition

    5: During driving

    6: During initialization

    7: During quick charge (Type 1)

    9: During quick charge (Type 2)
    CPU reset status ROM error/Stack error/CPU trap/Software/Watchdog 0/Watchdog 1/External input/Flash security/Irregular Displays reset status of main CPU
    Relay status Pre-charge/On/Off/Operating/Relay P check/Relay N check Displays status of each relay
    Nissan Ariya Vehicle total distance km Displays mileage (km) of Nissan Ariya vehicle
    Power switch ON time min Displays duration of power switch ON (min.)
    ASIC internal error (ALU) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC internal error (ALHVUV) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC internal error (HVMUXSWOC) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC internal error (VPTAT) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC internal error (ADCL) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC internal error (ADCH) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC internal error (LSAMP) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC internal error (VAA) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC internal error (RefV) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC internal error (OTemp) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC internal error (VHVHDRM) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC communication error (VHVOV) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC communication error (VHVUV) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC communication error (VAAUV) OK/NG Displays malfunction status of ASIC internal circuit.
    ASIC communication error (SCANDONE) OK/NG Displays the status of ASIC communication error.
    ASIC communication error (ESTM) OK/NG Displays the status of ASIC communication error.
    ASIC communication error (GNDL) OK/NG Displays the status of ASIC communication error.
    ASIC communication error (VDDL) OK/NG Displays the status of ASIC communication error.
    ASIC communication error (RX OC/SC) OK/NG Displays the status of ASIC communication error.
    Voltage disconnection open circuit (Data packet) OK/NG Displays the status of ASIC communication error.
    Voltage disconnection open circuit (16Mhz) OK/NG Displays the status of ASIC communication error.
    Voltage disconnection open circuit (Slave) OK/NG Displays the status of ASIC communication error.
    Voltage disconnection circuit error (BALEVEN OC) OK/NG Displays open circuit status of voltage measuring circuit
    Voltage disconnection circuit error (BALODD OC) OK/NG Displays open circuit status of voltage measuring circuit
    ASIC (BALSW) OK/NG Displays open circuit status of voltage measuring circuit
    ASIC (MUXseq) OK/NG Displays the short circuit status of capacity adjustment circuit.
    ASIC (MUXtcs) OK/NG Displays the short circuit status of capacity adjustment circuit.
    ASIC (CnSWn) OK/NG Displays open circuit status of voltage measuring circuit
    MAX internal resistance cell number

    Displays cell No. that shows maximum internal resistance.

    NOTE:

    Cell No. is shown 0 to 95. For comparison, Refer to Component Description.

    MIN internal resistance cell number

    Displays cell No. that shows minimum internal resistance.

    NOTE:

    Cell No. is shown 0 to 95. For comparison, Refer to Component Description.

    Maximum cell internal resistance value Ohm Displays the highest cell resistance value among all cells.
    Minimum cell internal resistance value Ohm Displays the lowest cell resistance value among all cells.

    *1: The items are the same as the items of freeze frame data of 1st trip DTC.

    HIGH VOLTAGE BATTERY 2 (Sub CPU)
    Monitored item Unit Remark
    Minimum voltage cell No

    Displays cell No. that shows minimum voltage.

    NOTE:

    Cell No. is shown 0 to 95. For comparison, Refer to Component Description.

    Relay status Pre-charge/On/Off/Operating/Relay P check/Relay N check Displays each relay status
    Data flash check OK/NG CPU data flash error is occurred
    Deep—Stop Mode Reset OK/NG Reset is occurred due to deep stop mode
    Power ON reset OK/NG Power ON reset is occurred
    Core voltage monitor reset OK/NG Power ON reset is occurred
    Low voltage indicator reset OK/NG Reset is occurred due to core low voltage detection circuit
    Clock monitor reset 2 OK/NG Reset is occurred due to clock monitor
    Clock monitor reset 1 OK/NG Reset is occurred due to clock monitor
    Clock monitor reset 0 OK/NG Reset is occurred due to clock monitor
    External reset OK/NG Reset is occurred due to input from external terminal
    Watchdog reset 1 OK/NG Reset is occurred due to watch dog timer
    Watchdog reset 0 OK/NG Reset is occurred due to watch dog timer
    Software reset OK/NG Software reset is occurred
    Trap error OK/NG CPU trap is occurred (Exception / Abnormal interruption)
    CPU stack OK/NG CPU stack abnormality (overflow or underflow) is occurred.
    ROM check OK/NG CPU ROM area error is occurred.
    RAM check OK/NG CPU ROM area error is occurred.

    *1: The items are the same as the items of freeze frame data of 1st trip DTC.

DATA MONITOR

NOTE:

The following table includes information (items) inapplicable to this Nissan Ariya vehicle. For information (items) applicable to this vehicle, refer to CONSULT display items.

HIGH VOLTAGE BATTERY (Main CPU)
Monitored item Unit Remark
Battery SOC % Displays battery charge level (SOC)
Battery pack voltage V Displays Li-ion battery voltage
Total battery voltage V Displays Li-ion battery total voltage
Maximum cell voltage V Displays highest cell voltage of each cell
Maximum voltage cell No

Displays cell No. that shows lowest voltage.

NOTE:

Cell No. is shown 0 to 95. For comparison, Component Description

Minimum cell voltage V Displays lowest cell voltage of each cell
Minimum voltage cell No

Displays cell No. that shows lowest voltage.

NOTE:

Cell No. is shown 0 to 95. For comparison, Component Description

Battery current A Displays Li-ion battery current value.
Power supply voltage V Displays 12 V power supply voltage to LBC.
Average temperature °C Displays average temperature of each module.
Lowest module temperature °C Displays lowest temperature of module.
Highest module temperature °C Displays highest temperature of module.
Cell voltage 01 – 96 V Displays voltage of each cell.
Cell controller status 08 – 01 Displays judge status of each cell controller.
Battery pack temp status Displays temperature status of each module.
Current sensor power supply voltage V Displays power supply voltage of battery current sensor.
Module temperature 01 – 16 °C Displays temperature of each module.
Battery SOC (Minimum) % Displays minimum amount of battery remaining energy record.
Battery SOC (Maximum) % Displays maximum amount of battery remaining energy record.
Battery pack activation time min Displays start up time of LBC.
Water temperature °C Displays batter coolant temperature.
Battery pack total mileage km Displays total mileage (km) of battery pack.
Interlock switch 1 Off/On/Short to power/Resistance NG/Short to ground Displays lock status between high voltage harness (FR) and service plug.
Interlock switch 2 Off/On/Short to power/Resistance NG/Short to ground Displays lock status of high voltage harness (RR).
Interlock switch 3 Off/On/Short to power/Resistance NG/Short to ground Displays lock status of high voltage harness (PTC).
Interlock switch 4 Off/On/Short to power/Resistance NG/Short to ground Displays lock status of high voltage harness (QC).
Relay 4 control request Off/Close Displays quick charge relay control request status.
Relay 4 status OK/NG Displays quick charge relay controller status
Highest temperature module Displays module No. that shows maximum temperature.
Lowest temperature module Displays module No. that shows minimum temperature.
CPU reset status RAM error/ROM error/Stack error/CPU trap/Software/Watchdog 0/Watchdog 1/External input/Flash security/Irregular Displays main CPU reset status.
Nissan Ariya Vehicle ID Displays VIN.
Nissan Ariya Vehicle total distance km Displays mileage of Nissan Ariya vehicle (km).
Power switch ON time min Displays duration of power switch ON (min).
Battery information % Displays information of SOH.
HIGH VOLTAGE BATTERY 2 (Sub CPU)
Monitored item Unit Remark
Maximum voltage cell No

Displays cell No. that shows maximum voltage.

NOTE:

Cell No. is shown 0 to 95. For comparison, Component Description

Minimum voltage cell No

Displays cell No. that shows minimum voltage.

NOTE:

Cell No. is shown 0 to 95. For comparison, Component Description

Insulation resistance Ohm

Displays insulation resistance value determined from insulation resistance sensor potential.

NOTE:

Since the insulation resistance is not displayed above the upper limit of the display range, it may differ from the actual insulation resistance value.

Insulation resistance sensor V Displays difference between the maximum voltage and the minimum voltage of the voltage amplitude of the insulation resistance sensor.
Sub CPU power supply voltage V Displays power supply voltage of sub-CPU of LBC
Relay status Pre-charge/On/Off/Operating/Relay P check/Relay N check Displays each relay status

WORK SUPPORT

Work item Description Usage
WRITE VIN DATA

NOTE:

The item is indicated, but not used.

OTA status reset

NOTE:

The item is indicated, but not used.

 

ECU IDENTIFICATION

Parts No. of Li-ion batter controller is displayed.

Monitor item Remark
ECU part number Displays parts No. of Li-ion battery controller (LBC)
 